Precast
Tunnel Segment - Bending Test
Barchip
reinforced precast segments of internal diameter 2.07m
were tested for bending loads.
The
load was applied via a hydraulic ram fitted to a steel
RSJ beam across the inside face of the segment.
28
day compressive strength cube results were 63.3 MPa.
Test
1 using 7Kg/m³ fibres.
Test date 07/10/02.
- First
crack occurred at 11.5 tonnes, no increase in load
could be applied.
- The
load then fell back to 9.5 tonnes and held.
- After
releasing the load the cracks closed up but could still
be seen.
Test 2 using 7Kg/m³ fibres.
Test date 07/10/02.
- First
crack occurred at 11.0 tonnes, an increase of load
could be applied to a maximum of 11.5 tonnes.
- The
load then fell back to 9.5 tonnes and held.
- After
releasing the load the cracks closed up but could still
be seen.

Precast Panel
Test
|