Barchip
fibre vs Steel mesh
The following pictures and graph form a brief summary of
concrete flooring research undertaken by Dr. Stefan Bernard
in Australia.
The aim of this analysis was to compare the relative performance
of steel mesh vs Barchip Kyodo synthetic fibre in a simulated
concrete floor failure.
The test method involved casting 1200mm (47") diameter
x 125mm (5") thick concrete panels and testing them
on a rubber support to simulate a subgrade soil reaction.
| No. |
Specimen |
Description |
1 |
F62 steel mesh |
6mm wire @ 200mm centres
(1/4" wire
@ 8" centres) |
2 |
Barchip Kyodo fibre |
3.5
kg per cubic metre
(6 lbs per cubic yard) |
Large 1200 mm diameter FRC panel at start of loading.
Large 1200 mm diameter FRC panel during test exhibiting
rotation